MCQ Practice Question
In a line-commutated AC rectifier, an SCR can turn OFF naturally when?
Correct Answer: A. Its current falls to zero and reverse voltage is available
Explanation: Natural commutation uses the AC source to bring current to zero and reverse-bias the outgoing SCR.
Reference: Standard power electronics: scr commutation