Measurements & Instrumentation MCQs

Practice Measurements & Instrumentation MCQs from fundamental concepts through intermediate, advanced and application-oriented questions. Each page contains up to 100 questions with answers and explanations where available.

Question 2
Measurements & InstrumentationMeasurement Errors

An error that remains approximately constant or changes predictably and can often be corrected by calibration is generally classified as?

  • ASystematic error
  • BRandom error
  • CGross error only
  • DQuantization noise only
Report an error
Correct Answer: A. Systematic error
Explanation: Systematic errors have identifiable, repeatable causes such as calibration or environmental effects and can often be compensated.
Reference: Standard measurements and instrumentation: measurement errors
Question 3
Measurements & InstrumentationMeasurement Errors

Unpredictable variations in repeated measurements are commonly called?

  • ARandom errors
  • BSystematic errors
  • CZero errors only
  • DScale factors
Report an error
Correct Answer: A. Random errors
Explanation: Random errors vary irregularly due to uncontrollable or statistical influences.
Reference: Standard measurements and instrumentation: measurement errors
Question 4
Measurements & InstrumentationMeasurement Errors

A gross error in measurement is most commonly associated with?

  • AHuman mistakes such as incorrect reading or recording
  • BFundamental thermal noise only
  • CPerfect calibration
  • DInfinite resolution
Report an error
Correct Answer: A. Human mistakes such as incorrect reading or recording
Explanation: Gross errors typically arise from mistakes in observation, recording, setup or calculation.
Reference: Standard measurements and instrumentation: measurement errors
Question 5
Measurements & InstrumentationCalibration

Calibration of an instrument means comparing its indication with?

  • AA known reference standard
  • BAn unknown load
  • CA random waveform
  • DOnly its own previous reading
Report an error
Correct Answer: A. A known reference standard
Explanation: Calibration establishes the relationship between an instrument's indication and values provided by suitable standards.
Reference: Standard measurements and instrumentation: calibration
Question 6
Measurements & InstrumentationInstrument Characteristics

The range of an instrument refers to?

  • AThe interval between minimum and maximum measurable input values
  • BOnly the maximum value
  • COnly the minimum value
  • DThe number of internal components
Report an error
Correct Answer: A. The interval between minimum and maximum measurable input values
Explanation: Range specifies the limits over which the instrument is intended to measure.
Reference: Standard measurements and instrumentation: instrument characteristics
Question 7
Measurements & InstrumentationMeasurement Fundamentals

Measurement is the process of comparing an unknown quantity with?

  • AAn accepted standard
  • BA random signal
  • COnly a digital display
  • DA power supply
Report an error
Correct Answer: A. An accepted standard
Explanation: Measurement determines the magnitude of a quantity by comparison with an accepted reference or standard.
Reference: Standard measurements and instrumentation: measurement fundamentals
Question 10
Measurements & InstrumentationMeasurement Fundamentals

The smallest change in input that an instrument can detect is called?

  • AResolution
  • BRange
  • CThreshold power
  • DDamping
Report an error
Correct Answer: A. Resolution
Explanation: Resolution is the smallest change in the measured quantity that can be distinguished by the instrument.
Reference: Standard measurements and instrumentation: measurement fundamentals
Question 11
Measurements & InstrumentationInstrument Characteristics

Sensitivity of an instrument is generally defined as?

  • AChange in output divided by corresponding change in input
  • BInput divided by time only
  • CMaximum input minus minimum input
  • DTrue value minus measured value
Report an error
Correct Answer: A. Change in output divided by corresponding change in input
Explanation: Sensitivity is the ratio of change in instrument output to the corresponding change in input.
Reference: Standard measurements and instrumentation: instrument characteristics
Question 17
Measurements & InstrumentationInstrument Characteristics

Hysteresis in an instrument means that, for the same input, the output may depend on?

  • AWhether the input was approached from increasing or decreasing direction
  • BOnly the power-supply frequency
  • COnly the display color
  • DThe number of terminals
Report an error
Correct Answer: A. Whether the input was approached from increasing or decreasing direction
Explanation: Hysteresis causes different indications for the same input depending on the previous direction of input change.
Reference: Standard measurements and instrumentation: instrument characteristics
Question 18
Measurements & InstrumentationInstrument Characteristics

Instrument drift refers to?

  • AA gradual change in indication with time when the measured quantity is unchanged
  • BAn instantaneous perfect response
  • CA deliberate range selection
  • DA fixed unit conversion
Report an error
Correct Answer: A. A gradual change in indication with time when the measured quantity is unchanged
Explanation: Drift is an undesired gradual change in instrument output with time despite an unchanged input.
Reference: Standard measurements and instrumentation: instrument characteristics
Question 19
Measurements & InstrumentationTransducers

A transducer converts?

  • AA physical quantity from one form into a corresponding usable signal
  • BAC power directly into mechanical work only
  • COnly digital data into text
  • DOnly resistance into heat
Report an error
Correct Answer: A. A physical quantity from one form into a corresponding usable signal
Explanation: In instrumentation, a transducer converts a measurand into another form, commonly an electrical signal suitable for measurement or processing.
Reference: Standard measurements and instrumentation: transducers
Question 21
Measurements & InstrumentationTemperature Measurement

A thermocouple operates primarily on the?

  • ASeebeck effect
  • BHall effect
  • CPhotoelectric effect only
  • DPiezoelectric effect
Report an error
Correct Answer: A. Seebeck effect
Explanation: A thermocouple generates a thermoelectric emf due to a temperature difference between junctions, known as the Seebeck effect.
Reference: Standard measurements and instrumentation: temperature measurement
Question 23
Measurements & InstrumentationDisplacement Measurement

An LVDT is primarily used to measure?

  • ALinear displacement
  • BTemperature
  • CHumidity only
  • DOptical wavelength
Report an error
Correct Answer: A. Linear displacement
Explanation: A Linear Variable Differential Transformer converts linear displacement into an electrical output.
Reference: Standard measurements and instrumentation: displacement measurement
Question 24
Measurements & InstrumentationStrain Measurement

A strain gauge is commonly used to measure strain through a change in?

  • AElectrical resistance
  • BMagnetic permeability only
  • COptical frequency only
  • DBattery voltage only
Report an error
Correct Answer: A. Electrical resistance
Explanation: Mechanical strain changes the gauge's dimensions and therefore its electrical resistance.
Reference: Standard measurements and instrumentation: strain measurement
Question 25
Measurements & InstrumentationStrain Measurement

The gauge factor of a resistive strain gauge is defined as?

  • AFractional change in resistance divided by strain
  • BStrain divided by resistance
  • CResistance multiplied by strain
  • DVoltage divided by current
Report an error
Correct Answer: A. Fractional change in resistance divided by strain
Explanation: Gauge factor GF=(ΔR/R)/ε, where ε is mechanical strain.
Reference: Standard measurements and instrumentation: strain measurement
Advertisement / responsive in-content slot
Question 26
Measurements & InstrumentationBridge Measurements

A Wheatstone bridge is widely used for precise measurement of?

  • AResistance or small resistance changes
  • BFrequency only
  • CInductance only
  • DOptical power only
Report an error
Correct Answer: A. Resistance or small resistance changes
Explanation: The Wheatstone bridge compares resistance ratios and is widely used with resistive sensors such as strain gauges.
Reference: Standard measurements and instrumentation: bridge measurements
Question 27
Measurements & InstrumentationAnalog Instruments

A PMMC instrument is primarily suitable for direct measurement of?

  • ADC only
  • BAC only
  • CBoth AC and DC without any additional circuit
  • DMicrowave frequency only
Report an error
Correct Answer: A. DC only
Explanation: A PMMC movement responds to the average value and reverses torque with current direction, so it is inherently suited to DC. AC measurement requires rectification.
Reference: Standard measurements and instrumentation: analog instruments
Question 28
Measurements & InstrumentationDC Bridges

A Kelvin double bridge is especially suitable for measuring?

  • AVery low resistance
  • BVery high frequency
  • CCapacitance only
  • DTemperature directly
Report an error
Correct Answer: A. Very low resistance
Explanation: The Kelvin double bridge minimizes errors due to lead and contact resistance, making it suitable for low-resistance measurement.
Reference: Standard measurements and instrumentation: dc bridges
Question 29
Measurements & InstrumentationAC Bridges

A Maxwell bridge is commonly used to measure an unknown?

  • AInductance
  • BCapacitance only
  • CFrequency only
  • DDC voltage
Report an error
Correct Answer: A. Inductance
Explanation: The Maxwell bridge determines an unknown inductance by comparison with known resistance and capacitance standards.
Reference: Standard measurements and instrumentation: ac bridges
Question 30
Measurements & InstrumentationAnalog Instruments

The deflecting torque of an ideal PMMC instrument is proportional to?

  • ACurrent through the moving coil
  • BSquare of current
  • CFrequency only
  • DResistance squared
Report an error
Correct Answer: A. Current through the moving coil
Explanation: With a uniform permanent-magnet field, PMMC deflecting torque is directly proportional to coil current.
Reference: Standard measurements and instrumentation: analog instruments
Question 31
Measurements & InstrumentationAC Bridges

A Schering bridge is commonly used for measurement of?

  • ACapacitance and dielectric loss
  • BInductance only
  • CDC current only
  • DMechanical displacement
Report an error
Correct Answer: A. Capacitance and dielectric loss
Explanation: The Schering bridge is widely used for capacitance measurement and evaluation of dielectric loss or dissipation factor.
Reference: Standard measurements and instrumentation: ac bridges
Question 32
Measurements & InstrumentationAnalog Instruments

A moving-iron instrument can normally be used for?

  • ABoth AC and DC
  • BDC only
  • CAC only above 1 MHz
  • DTemperature only
Report an error
Correct Answer: A. Both AC and DC
Explanation: Moving-iron torque depends approximately on the square of current, so its direction is independent of current polarity and it can measure AC or DC.
Reference: Standard measurements and instrumentation: analog instruments
Question 33
Measurements & InstrumentationAC Bridges

A Wien bridge is well known for measurement of?

  • AFrequency
  • BVery low resistance
  • CDC current
  • DMagnetic flux only
Report an error
Correct Answer: A. Frequency
Explanation: The Wien bridge uses frequency-dependent RC arms and is commonly used for audio-frequency measurement and oscillator circuits.
Reference: Standard measurements and instrumentation: ac bridges
Question 34
Measurements & InstrumentationAnalog Instruments

The scale of a PMMC instrument is approximately?

  • AUniform
  • BHighly logarithmic
  • CSquare-law crowded at upper end
  • DIndependent of current
Report an error
Correct Answer: A. Uniform
Explanation: Because deflection is proportional to current, a PMMC instrument has an approximately uniform scale.
Reference: Standard measurements and instrumentation: analog instruments
Question 35
Measurements & InstrumentationAnalog Instruments

The scale of a basic moving-iron instrument is generally?

  • ANon-uniform
  • BPerfectly uniform
  • CDigital
  • DLinear only at zero frequency
Report an error
Correct Answer: A. Non-uniform
Explanation: Moving-iron deflecting torque is nonlinear with current, so its scale is generally non-uniform and crowded near the lower end.
Reference: Standard measurements and instrumentation: analog instruments
Question 36
Measurements & InstrumentationRange Extension

To convert a sensitive galvanometer or meter movement into a higher-range ammeter, a low resistance is connected?

  • AIn parallel as a shunt
  • BIn series as a multiplier
  • CAcross the power supply only
  • DIn series with the load and meter separately
Report an error
Correct Answer: A. In parallel as a shunt
Explanation: A low-value shunt bypasses most of the measured current around the sensitive meter movement.
Reference: Standard measurements and instrumentation: range extension
Question 37
Measurements & InstrumentationRange Extension

To extend the voltage range of a voltmeter movement, a high resistance is connected?

  • AIn series with the movement
  • BIn parallel with the movement
  • CAcross the current source only
  • DIn parallel with a short circuit
Report an error
Correct Answer: A. In series with the movement
Explanation: A series multiplier resistance limits current through the meter movement at higher applied voltages.
Reference: Standard measurements and instrumentation: range extension
Question 40
Measurements & InstrumentationLoading Effect

An ideal ammeter should have internal resistance of?

  • AZero
  • BInfinite
  • C1 kohm
  • DEqual to load resistance
Report an error
Correct Answer: A. Zero
Explanation: An ammeter is connected in series, so ideally its resistance is zero to avoid altering circuit current.
Reference: Standard measurements and instrumentation: loading effect
Question 41
Measurements & InstrumentationLoading Effect

An ideal voltmeter should have internal resistance of?

  • AZero
  • BInfinite
  • CEqual to source resistance
  • DOne ohm
Report an error
Correct Answer: B. Infinite
Explanation: A voltmeter is connected in parallel and ideally draws no current, requiring infinite input resistance.
Reference: Standard measurements and instrumentation: loading effect
Question 42
Measurements & InstrumentationLoading Effect

A voltmeter with finite input resistance connected across a circuit can cause?

  • ALoading error
  • BZero frequency
  • CInfinite source voltage
  • DNo effect under any condition
Report an error
Correct Answer: A. Loading error
Explanation: The voltmeter draws current and changes the effective circuit resistance, potentially altering the voltage being measured.
Reference: Standard measurements and instrumentation: loading effect
Question 43
Measurements & InstrumentationPotentiometers

A potentiometer is considered a null-type instrument because at balance it?

  • ADraws essentially no current from the source being measured through the detector branch
  • BAlways draws maximum current
  • CUses no reference voltage
  • DMeasures only resistance
Report an error
Correct Answer: A. Draws essentially no current from the source being measured through the detector branch
Explanation: At null balance there is no detector current, enabling accurate comparison without loading the measured source in the ideal case.
Reference: Standard measurements and instrumentation: potentiometers
Question 44
Measurements & InstrumentationPotentiometers

A DC potentiometer can be used to measure an unknown emf by?

  • AComparing it with a known reference under null condition
  • BMeasuring its frequency
  • CConverting it directly to inductance
  • DShort-circuiting the source
Report an error
Correct Answer: A. Comparing it with a known reference under null condition
Explanation: A potentiometer balances the unknown voltage against a calibrated potential drop derived from a reference.
Reference: Standard measurements and instrumentation: potentiometers
Question 46
Measurements & InstrumentationAC Bridges

In an AC bridge at balance, the detector current is ideally?

  • AZero
  • BMaximum
  • CEqual to supply current
  • DAlways 1 A
Report an error
Correct Answer: A. Zero
Explanation: At bridge balance the detector terminals are at equal potential, so ideally no detector current flows.
Reference: Standard measurements and instrumentation: ac bridges
Question 50
Measurements & InstrumentationDigital Instruments

A 3.5-digit digital meter is commonly capable of displaying up to approximately?

  • A1999 counts
  • B999 counts
  • C9999 counts
  • D65535 counts
Report an error
Correct Answer: A. 1999 counts
Explanation: A conventional 3.5-digit display has three full digits plus a leading half digit that is typically 0 or 1, giving a maximum display around 1999.
Reference: Standard measurements and instrumentation: digital instruments
Advertisement / responsive in-content slot
Question 51
Measurements & InstrumentationDigital Instruments

A 4-bit ideal ADC provides how many quantization levels?

  • A4
  • B8
  • C16
  • D32
Report an error
Correct Answer: C. 16
Explanation: An N-bit ADC provides 2^N ideal quantization codes; for N=4 this is 16 levels.
Reference: Standard measurements and instrumentation: digital instruments
Question 52
Measurements & InstrumentationCRO & Oscilloscopes

In a conventional CRO, the vertical deflection system is primarily used to represent?

  • ASignal amplitude
  • BTime only
  • CPower factor only
  • DFrequency counter output only
Report an error
Correct Answer: A. Signal amplitude
Explanation: The input signal is normally applied to the vertical channel, so vertical displacement represents instantaneous signal voltage.
Reference: Standard measurements and instrumentation: cro & oscilloscopes
Question 54
Measurements & InstrumentationDigital Oscilloscopes

A digital storage oscilloscope differs from a basic analog CRO mainly because it can?

  • ADigitize and store acquired waveforms
  • BMeasure only DC
  • COperate without any sampling
  • DDisplay no transient signals
Report an error
Correct Answer: A. Digitize and store acquired waveforms
Explanation: A DSO samples the input, converts it to digital data and stores the waveform for processing and display.
Reference: Standard measurements and instrumentation: digital oscilloscopes
Question 55
Measurements & InstrumentationInstrument Transformers

A current transformer is primarily used to?

  • AScale large AC current to a smaller measurable current
  • BIncrease DC voltage
  • CMeasure temperature
  • DGenerate radio frequency
Report an error
Correct Answer: A. Scale large AC current to a smaller measurable current
Explanation: A CT reproduces a scaled version of primary AC current for metering and protection.
Reference: Standard measurements and instrumentation: instrument transformers
Question 56
Measurements & InstrumentationInstrument Transformers

The secondary of an energized current transformer should generally not be?

  • AOpen-circuited
  • BConnected to its rated burden
  • CShorted through an ammeter of low impedance
  • DGrounded at one designated point where required
Report an error
Correct Answer: A. Open-circuited
Explanation: Opening an energized CT secondary can produce dangerously high secondary voltage and excessive core flux.
Reference: Standard measurements and instrumentation: instrument transformers
Question 57
Measurements & InstrumentationInstrument Transformers

A potential transformer is used mainly to?

  • AStep down high AC voltage for measurement and protection
  • BMeasure only resistance
  • CConvert DC current to AC
  • DIncrease current for welding
Report an error
Correct Answer: A. Step down high AC voltage for measurement and protection
Explanation: A PT/VT provides an accurately scaled lower voltage for instruments and protective relays.
Reference: Standard measurements and instrumentation: instrument transformers
Question 59
Measurements & InstrumentationPower Measurement

A single-phase electrodynamometer wattmeter measures?

  • AReal power
  • BReactive power only
  • CFrequency only
  • DResistance only
Report an error
Correct Answer: A. Real power
Explanation: A wattmeter's average deflecting torque is proportional to the average product of voltage and current, corresponding to real power.
Reference: Standard measurements and instrumentation: power measurement
Question 63
Measurements & InstrumentationThree-Phase Measurement

For a balanced three-phase load at unity power factor, the two wattmeters in the two-wattmeter method ideally read?

  • AEqual positive values
  • BEqual and opposite values
  • COne zero and one negative
  • DBoth zero
Report an error
Correct Answer: A. Equal positive values
Explanation: At φ=0, W1=VLIL cos30° and W2=VLIL cos30°, so the readings are equal and positive.
Reference: Standard measurements and instrumentation: three-phase measurement
Question 64
Measurements & InstrumentationCRO & Oscilloscopes

The time-base generator of a CRO normally produces a?

  • ASawtooth waveform
  • BPure DC level
  • CSquare-law current only
  • DRandom waveform
Report an error
Correct Answer: A. Sawtooth waveform
Explanation: A sawtooth or ramp voltage sweeps the electron beam horizontally at an approximately uniform rate.
Reference: Standard measurements and instrumentation: cro & oscilloscopes
Question 73
Measurements & InstrumentationSignal Conditioning

An instrumentation amplifier is especially useful for sensor signals because it typically provides?

  • AHigh input impedance and high common-mode rejection
  • BVery low input impedance and zero gain
  • COnly digital output
  • DNo differential amplification
Report an error
Correct Answer: A. High input impedance and high common-mode rejection
Explanation: Instrumentation amplifiers are designed for accurate amplification of small differential signals in the presence of common-mode voltage.
Reference: Standard measurements and instrumentation: signal conditioning
Question 74
Measurements & InstrumentationData Acquisition

A low-pass anti-aliasing filter is placed before an ADC mainly to?

  • ALimit input bandwidth before sampling
  • BIncrease aliasing
  • CConvert digital data to analog
  • DGenerate quantization levels
Report an error
Correct Answer: A. Limit input bandwidth before sampling
Explanation: The filter attenuates frequency components that could fold into the sampled baseband and cause aliasing.
Reference: Standard measurements and instrumentation: data acquisition
Question 75
Measurements & InstrumentationData Acquisition

An ideal 10-bit ADC has how many output codes?

  • A256
  • B512
  • C1024
  • D2048
Report an error
Correct Answer: C. 1024
Explanation: An N-bit ADC provides 2^N codes, so 2^10=1024.
Reference: Standard measurements and instrumentation: data acquisition
Advertisement / responsive in-content slot
Question 81
Measurements & InstrumentationADC & Data Acquisition

A successive-approximation ADC determines the digital code primarily by?

  • ABinary search
  • BCounting down from infinity
  • CFrequency multiplication only
  • DAnalog integration without comparison
Report an error
Correct Answer: A. Binary search
Explanation: A SAR ADC tests bits from MSB to LSB using a comparator and internal DAC, effectively performing a binary search.
Reference: Standard measurements and instrumentation: adc & data acquisition
Question 82
Measurements & InstrumentationADC & Data Acquisition

A flash ADC is known for high conversion speed because it uses?

  • AMany comparators operating in parallel
  • BOne comparator in a long serial search
  • CA mechanical pointer
  • DA Wheatstone bridge only
Report an error
Correct Answer: A. Many comparators operating in parallel
Explanation: A flash ADC compares the input against many reference levels simultaneously, giving very fast conversion.
Reference: Standard measurements and instrumentation: adc & data acquisition
Question 83
Measurements & InstrumentationData Acquisition

A sample-and-hold circuit in a data-acquisition system is used to?

  • AHold the analog input approximately constant during conversion
  • BGenerate random samples
  • CEliminate the ADC
  • DConvert digital output to AC power
Report an error
Correct Answer: A. Hold the analog input approximately constant during conversion
Explanation: The hold capacitor maintains the sampled input level while the ADC completes conversion.
Reference: Standard measurements and instrumentation: data acquisition
Question 86
Measurements & InstrumentationTransducers

A piezoelectric transducer is particularly suitable for measurement of?

  • ADynamic force, pressure or vibration
  • BTrue static displacement over indefinitely long periods
  • CDC resistance only
  • DHumidity only
Report an error
Correct Answer: A. Dynamic force, pressure or vibration
Explanation: Piezoelectric sensors generate charge under mechanical stress and are especially suited to dynamic measurements; charge leakage limits true static measurement.
Reference: Standard measurements and instrumentation: transducers
Question 87
Measurements & InstrumentationTransducers

A Hall-effect sensor is commonly used to sense?

  • AMagnetic field
  • BHumidity only
  • CAcoustic pressure only
  • DChemical pH only
Report an error
Correct Answer: A. Magnetic field
Explanation: The Hall effect produces a transverse voltage in a current-carrying material subjected to a magnetic field.
Reference: Standard measurements and instrumentation: transducers
Question 89
Measurements & InstrumentationTransducers

An inductive proximity sensor is commonly used for detecting?

  • AMetallic objects
  • BOnly transparent liquids
  • COnly temperature
  • DOnly light intensity
Report an error
Correct Answer: A. Metallic objects
Explanation: Inductive proximity sensors generate electromagnetic fields and detect changes caused primarily by nearby conductive metallic targets.
Reference: Standard measurements and instrumentation: transducers
Question 90
Measurements & InstrumentationIndustrial Instrumentation

In a 4-20 mA industrial current loop, the value 4 mA commonly represents?

  • ALive zero or lower-range value
  • BFull-scale value
  • CPower failure by definition
  • DExactly 25% of every physical quantity
Report an error
Correct Answer: A. Live zero or lower-range value
Explanation: The 4 mA lower endpoint is a live zero, helping distinguish a valid minimum reading from certain fault conditions such as an open loop.
Reference: Standard measurements and instrumentation: industrial instrumentation
Question 93
Measurements & InstrumentationSignal Conditioning

Common-mode rejection ratio of an instrumentation amplifier is the ratio of?

  • ADifferential gain to common-mode gain
  • BCommon-mode gain to differential gain
  • COutput resistance to input resistance
  • DBandwidth to gain
Report an error
Correct Answer: A. Differential gain to common-mode gain
Explanation: CMRR=Ad/Acm and indicates how strongly the amplifier rejects signals common to both inputs.
Reference: Standard measurements and instrumentation: signal conditioning
Question 95
Measurements & InstrumentationSignal Conditioning

A CMRR of 10000 expressed in decibels is?

  • A40 dB
  • B60 dB
  • C80 dB
  • D100 dB
Report an error
Correct Answer: C. 80 dB
Explanation: CMRR(dB)=20log10(10000)=20×4=80 dB.
Reference: Standard measurements and instrumentation: signal conditioning
Question 96
Measurements & InstrumentationAdvanced Measurement

A true-RMS voltmeter is valuable for nonsinusoidal waveforms because it measures a quantity related to?

  • AHeating or power-equivalent value
  • BPeak value only
  • CAverage value with no waveform dependence
  • DFrequency only
Report an error
Correct Answer: A. Heating or power-equivalent value
Explanation: RMS is the effective value that produces the same heating effect in a resistor as an equivalent DC value.
Reference: Standard measurements and instrumentation: advanced measurement
Question 98
Measurements & InstrumentationDynamic Characteristics

A smaller time constant in a first-order measuring instrument generally means?

  • AFaster response
  • BSlower response
  • CLower static sensitivity necessarily
  • DInfinite hysteresis
Report an error
Correct Answer: A. Faster response
Explanation: A smaller time constant causes the exponential transient to decay more quickly, producing a faster response.
Reference: Standard measurements and instrumentation: dynamic characteristics
Question 99
Measurements & InstrumentationDynamic Characteristics

The term dead time in an instrument refers to?

  • AA delay before the output begins responding to an input change
  • BThe final steady-state error only
  • CThe calibration interval
  • DThe full-scale value
Report an error
Correct Answer: A. A delay before the output begins responding to an input change
Explanation: Dead time is the interval between an input change and the beginning of the observable output response.
Reference: Standard measurements and instrumentation: dynamic characteristics
Question 100
Measurements & InstrumentationDynamic Characteristics

A zero-order instrument ideally produces an output that is?

  • AInstantaneously proportional to the input
  • BAlways delayed by one time constant
  • CAlways oscillatory
  • DIndependent of input
Report an error
Correct Answer: A. Instantaneously proportional to the input
Explanation: An ideal zero-order instrument has no dynamic energy-storage effect and follows the input proportionally without dynamic lag.
Reference: Standard measurements and instrumentation: dynamic characteristics
Advertisement / responsive in-content slot
1 2