MCQ Practice Question
In an analog sample-and-hold circuit, acquisition time is the time required after entering sample mode for the held voltage to?
Correct Answer: A. Settle sufficiently close to the input value
Explanation: Acquisition time measures how long the circuit needs to charge its hold capacitor and settle to the new sampled input within a specified error.